Closed loop synchronous system a. As shown in the figure, the synchronizationvalve controls a certain synchronization error.The detection error signal of the displacement or speed sensor is differentially amplified and the electronic control valve discharges the overspeed oil circuit to fine-tune the synchronization error. b. The electric control valve can use solenoid valve,proportional valve and servo valve. The former has low cost and the latter has high precision. The control accuracy of the solenoid valve is mm-level, the proportional valve is the dmm-level and the servo valve is cmm-level. c. The synchronization error includes the static and dynamic response results, which are specifically based on the value of the transfer function obtained after the electro-hydraulic synthesis is given. d. The primary control function of the synchronous valve is to reduce the diameter specification of the electric control valve and reduce the cost of the system. e. The electro-hydraulic multi-cylinder control adopts a single-cylinder oil supplement or oil drain circuit. |
|
Lifting or panning synchronization loop | Oil inlet synchronization circuit: the synchronization valve is connected to the rodless cavity side of the cylinder. Generally used in lifting and horizontal push synchronization systems. The size of the valve is selected according to the pump or diversity flow. Precautions: a. W is the potential energy load. The balance circuit must be connected in series at the C port of the synchronous valve. b. The pipeline diameter should meet the standard requirements, and the resistance of the two pipelines between the cylinder and the valve should be the same as possible. c. The influence of the cylinder gear ratio on the pressure and flow rate should be considered when selecting the synchronization valve specifications. |
Suspended (negative load) synchronous circuit | Synchronous circuit of oil outlet. The synchronization valve is connected to the rod cavity side of the cylinder. Generally used for suspending potential energy load synchronization system. The selection of valve specifications should consider the flow rate of the cylinder after shifting. If the valve is installed on the rodless cavity side, the cylinder with rod cavity must be equipped with a balance circuit to prevent overspeed and loss of control. The precautions are the same as above. In addition, the system synchronization valve with a cylinder gear ratio greater than 2 should not be installed in the rod cavity of the cylinder, otherwise the pressure in the rod cavity will double when the cylinder is extended, which will damage the synchronization valve. |
Three cylinder series synchronous loop | Series three cylinder synchronous circuit. With a outlet 1:2 and a outlet: 1:1 synchronous valve connected in series into a three-cylinder synchronous loop. For lifting and recumbent systems. The pressure loss and synchronization error in the loop is the sum of the two valves. |
Three cylinders connected with synchronous circuit | Parallel three-cylinder synchronous loop. With two equal ratio synchronous valve and connected into a three cylinder synchronous circuit. The size of the rod-cavity synchronous valve is smaller than that of the rod-cavity side valve due to the variable speed ratio of the cylinder. The potential energy load should add a balance loop, and the pressure loss in the loop = (1+1/ I) ΔP (I cylinder speed ratio). Synchronization error is the vector sum of two valves. If the error of the two valves is equal, the synchronization error after the speed and slow collocation =δ+ (-δ) +δ=δ. |
Four cylinder series synchronous loop | Four cylinder synchronous loop connected in series. For lifting and recumbent systems. The pressure loss and synchronization error in the loop are the sum of the two stage valves. Note: A. It is suggested that port A\B of the second stage synchronous valve is supported by the oil cylinder to connect the diagonal oil cylinder port of the platform. B, the cylinder distribution is "one" word to arrange the second stage synchronous valve A\B port shall be symmetrically connected with both ends of the cylinder port. |
Four cylinders connected with synchronous circuit | Parallel four cylinder synchronous loop. With four equal ratio synchronous valve speed matching and connection into a synchronous circuit. This is the most efficient connection with a synchronous valve to control each cylinder. The calculation of pressure loss and synchronization error is the same as for the three-cylinder parallel circuit. Note: A. For the cylinder supported platform, it is suggested that the synchronous valve A\B of the lower chamber of the cylinder be connected to the diagonal cylinder port of the platform. B. The cylinder distribution is arranged in A "one" word, the cylinder lower chamber synchronous valve A\B port is symmetrically connected with the two ends of the cylinder port |
Synchronous valve open-circuit method of multi-cylinder synchronous circuit | This connection method is mostly used for multi-cylinder synchronous loop with odd number of cylinders or different cylinder diameters. The characteristic is that each pair of oil cylinder has a synchronous valve control, in the debugging synchronous process is more intuitive and convenient. The overall synchronization error is added up one by one. Note: A. The synchronous control response between the head and tail cylinders is slow, so the two cylinders with variable loads had better be installed in a valve control. B, according to the vector synchronization error of a single synchronous valve for comprehensive matching to obtain the best synchronization effect. |
Synchronous valve closed circuit method of multi-cylinder synchronous circuit | This connection method can only be used for even number of cylinders of multi-cylinder synchronous loop. It features two valves for each cylinder. So the error is smaller. When the loop needs to repair the synchronization error, replace a valve with a three-way body or take out the secondary valve sleeve of a valve to adjust the error according to the 8 loop, and then restore the vacant valve to its original condition. When the error of one valve is large, the resistance of the circuit will increase. The synchronization valve adjustment with the fault can be found by the above method |
Plane load synchronous valve cross-connected multi-cylinder synchronous circuit | The loop uses a platform frame with good stiffness to offset the synchronization error between the two valves. According to the left figure, if the platform stiffness is good enough, only two valves can be used to control the diagonal to complete the synchronization. The circuit is characterized by small error, fast response, small pressure loss and cost saving. |