Mounting position | Slective |
|||
The highest ambient temperature | t | °C | To 50 |
|
Weight | With one solenoid valve | m | kg | 1.45 |
With two solenoid valve | m | kg | 1.95 |
|
Max working pressure | Port A, B, P | P | MPa | 31.5 |
Port T | P | MPa | To 21(=); to 16(-) If working pressure exceeds allowance pressure for spool A and B of the valve port T must be as leakage port |
|
Max flow | qv | L/min | To 80(=); To 60(~) |
|
Flow area (switching position O ) | Spool Q | A | mm2 | About rated area 6% |
Spool W | A | mm2 | About rated area 3% |
|
Hydraulic oil 1) apply to perbunan seal viton seal 2) for use only viton seal | Mineral oil (HL,HLP) DIN51 524 1); Quick biologic dissolve oil according to VDMA 24 568; HETG (rape seed oil); HEPG(polyglycol); HEES(synthetic ester)2); Other oil as required |
|||
Oil temperature changing range | °C | -30 to +80(with perbunan seal) |
||
-20 to +80 (with viton seal) |
||||
Viscosity range | mm2/s | 2.8 to 500 |
||
Contaminant degree | The high contaminant class of oil is the ninth class of NAS 1638 recommend to use the oil filter with minimal filter fineness β10≥75 |
Volt type | DC | AC |
||
Available volt | U | V | 12, 24, 42, 60, 96, 110, 180, 205,220 | 42, 110, 120, 220, 50/60Hz |
Allowed volt (allowance volt ) | % | ±10 | ||
Power requirement | P | W | 30 | - |
Power keep | P | VA | - | 50 |
Power impetus | P | VA | - | 220 |
Work repeating | 100% | 100% |
||
Time repeating press on | T | ms | 25 to 45 | 10 to 20 |
ISO 6403 off | T | ms | 10 to 25 | 15 to 40 |
Switching frequency | time/h | To 15000 | To 7200 |
|
Insulation degree according to DIN40050 | IP65 | IP65 |
||
Coil temperatare | °C | To +150 | To+180 |
|
It is correlative stipulated electric wire must be grounded |
7 symbol "R"is on switching position A-B |
7 symbol "R"is on switching position A-B 8 symbol "G"and "T"is on center position P-T | Switching function limit (be measured when ν=41mm2 /s t=50°C) | Working limit for giving is useful for two direction flowing condition (as for P port flow to A of returning of B to T at the same time ) When single direction flow (if the port from P to A B is plugged )because of flow strenth in the valve allowance switching limit may fall cloun Working limit is measured when solenoid is on working temperature owing volt 10% and the reservoir without bearing pressure | DC solenoid Exemplification:G24:24V | AC solenoid Exemplification:W230:230V,5Hz | AC solenoid Exemplification:W230:230V,5Hz |
1.1 Solenoid "a"(grey plug-in connector) 1.2 Solenoid "b" (black plug-in connector) 2. Manual urgent operation 3.Size of solenoid "N"with manual urgent operation 4.Plug-in connector according to DIN43650 5.Name plate 6.O-ring 7. For use one plug of solenoid valve 8. Take off plug-in connector for space request 9. Take off coil for space request 10. Fixed screw nut tightened torque M =4Nm 11.Mounting surface according to DIN24 340, A type ISO 4401 and CETOP-RP 121 H bed plate G341/01(G1/4") G342/01(G3/8") G502/01(G1/2") Fixed screw of the valve M5X50 GB70-85-10.9 Tightened torque MA=8.9Nm |
External dimensions: valve with AC solenoid cooperated with surface fine machining requirement 1.Connection surface of the valve 2.Plate tangent 3.Fixed screw of the valve 4. Fixed screw of the valve four pieces M5X50 GB70-85-10.9 torque 9N.m |